Product Introduction

Standard Type

Ceiling mounted purification function dedicated type_structure map of air purification+ virus prevention product
img

Enforced type of ceiling mounted heat recovery ventilation device purification system

System of ventilation+air purification (application of not lower than HEPA Filter H12 grade) +system for virus prevention (application of Cluster ionizer or UV sterilization Lamp)

img
Ceiling mounted purification function dedicated type_structure map of air purification+ virus prevention product

Heat recovery ventilation device specification of purification specialized type(purification+sterilization+ virus prevention)

Model Main purpose
Target
Air flow intensity MAX
(CMH)
Product standard
(L*H*W)
Standard operation specification Power consumption
(W)
Power
KAV - 10CP Hospital, Patient’s room 100 540*190*350 5 stages for air flow intensity control
(economy, light, medium, strong, very strong),
function of inside device cleaning operation
<I.C.W operation>
50 220V, 60Hz
KAV - 15CP 150 600*240*400 60
KAV - 25CP 250 730*270*500 120
KAV - 35CP hospital, school, kindergarten and other facilities
(Buildings for special purpose)
350 860*330*600 125
KAV - 50CP 500 860*190*350 150

Standard operation function for heat recovery ventilation device specialized in purifying function(purifying+sterilization+virus prevention)

Operation mode Running mode
At the Initial operation of device(turned on)
I.C.W/P.D.T(Indoor Cleaning Work / Particle Down Time)
I.C.W operation/EA FAN in very strong operation mode for 20seconds
Outside air MD: OFF
P.D.T preventing the re-influx of exhaust dust
Maintain the device turned off for 3 seconds
Negative pressure system operation(operation with exhaust priority)- operation for removing droplet EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Positive pressure operation(operation with supply priority) – operation for reducing CO2 EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Operation for ventilation EA, SA FAN – operation in the same constant intensity of air flow
5 stages of air flow intensity control economy, light, medium, strong, very strong
Virus prevention system installed Optional application of UV Lamp or CLUSTER IONIZER

Standard operation function for heat recovery ventilation device specialized in purifying function(purifying+sterilization+virus prevention)

  • · Efficiency of heat exchange: air conditioning: not greater than 25%, heating: not greater than 55%
  • · 5 stages of air flow intensity(upgraded control mode of air flow intensity setting – application of negative·positive pressure operation system as standard)
  • · Model of design patent registration (patent number 30-1158848)
  • · Function of ICW operation: inside device cleaning operation function(after 20seconds of initial exhausting operation it stops for 3 seconds and then be operated normally) to prevent the re-influx of adhesive pollutant(odor, dust)
  • · Equipped with virus prevention system: optional application of UV Lamp or Cluster Ionizer is possible
  • · Application of centralized control system : control over up to 24 Porte is applied
  • · Filter application for removing fine dust and odor: application of higher than HEPA-H12 grade / carbon coated nonwoven PRE Filter
Ceiling mounted heat recovery ventilation device standard type for energy efficiency total heat exchanger

Enforced type of ceiling mounted heat recovery ventilation device purification system

img
img

Ceiling mounted type(side access hall type) specification/data

Model Air flow intensity MAX
(CMH)
Product standard
(L*H*W)
Connector standard
(Flange)Φ
Consumption of power
(W)
Power
KAV - 10CPS 100 540*300*350 100/65 under 50 220V
60Hz
KAV - 15CPS 150 600*350*400 125/100 under 100
KAV - 25CPS 250 730*400*500 150/125 under 150
KAV - 35CPS 350 850*500*650 200/150 under 200
KAV - 50CPS 500 850*500*650 200 under 250
KAV - 80CPS 800 1400*600*1000 250 under 450
KAV - 100CPS 1000 1400*600*1000 250 under 480
KAV - 150CPS 1500 1540*600*1100 300 under 950
KAV - 200CPS 2000 1540*600*1100 300 under 1200
KAV - 250CPS 2500 1720*704*1100 350/300 under 1200

Ceiling mounted type(side access hole type 100~1000CMH), ceiling exposure type(downward access hole type-100~350CMH)

Operation mode Running mode
At the Initial operation of device(turned on)
I.C.W/P.D.T(Indoor Cleaning Work / Particle Down Time)
I.C.W operation/EA FAN in very strong operation mode for 20seconds
SA FAN - OFF
Outside air MD OFF / P.D.T prevention for the re-influx of exhaust dust
10 seconds of being turned off for the entire device
Negative pressure system operation(operation with exhaust priority)- operation for removing droplet EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Positive pressure operation(operation with supply priority) – operation for reducing CO2 EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Operation for ventilation EA, SA FAN – operation in the same constant intensity of air flow/td>
Virus prevention system UV Lamp(OA, RA section) multi operation
Air flow intensity control by 5 stages Economy, light, medium, strong, very strong

Features of ceiling mounted standard type of energy efficiency heat recovery ventilation

  • · Heat exchange efficiency standard customized (air conditioning not less than 45%, heating not less than 75%) high efficiency Element applied
  • · Air flow intensity control by 5 stages :economy, medium, strong, very strong(negative and positive pressure system operation)
  • · Function of ICT operation: function of inside device cleaning operation for preventing the re-influx of adhesive pollutant(odor/dust) in the device
  • · Application of centralized control: capability of control of up to 24 Pot
  • · Specification of Filter application: PRE Filter– carbon coated nonwoven Filter / Medium Filter 10~20T- grade of H12 Hepa Filter
Ceiling exposure/wall mounted heat recover ventilation device energy efficiency standard type total heat exchanger Structure map / standard specification feature

Exposure installation(ceiling mounted) heat recovery ventilation device structure map

img

Exposure installation(wall mounted) heat recovery ventilation device structure map

img

Standard specification/data of export model for purification ventilation device

Model Air flow intensity MAX
(CMH)
Product standard
(L*H*W)
Modification of operation Consumption of power
(W)
Power
KAV - 350SB 350 870*605*350 Air flow intensity control by 5 stages
(economy, light, medium, strong, very strong)
125 DC12V
KAV - 250SB 250 700*500*240 120
KAV - 150SB 150 700*500*255 60
KAV - 100SB 100 540*350*190 50
KAV - 50SB 50 400*250*150 30

Export model (Ceiling type/wall mounted type) purification ventilation device Operation function

Operation mode Running mode
At the Initial operation of device(turned on)
I.C.W/P.D.T(Indoor Cleaning Work / Particle Down Time)
I.C.W operation / EA FAN- operation in more strong stage of fan intensity for 20 seconds
SA FAN - OFF
Outside air MD: OFF/P.D.T preventing the re-influx of exhaust dust
10 seconds of being turned off for the entire device
Negative pressure system operation(operation with exhaust priority)- operation for removing droplet EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Interoperation of air conditioning and heating (operation of heat storage) air conditioner and heater
System operation at running
EA FAN – OFF/outside air MD: OFF
SA FAN–economy(ON) / heat storage MD: Open
Positive pressure operation(operation with supply priority) – operation for reducing CO2 EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Operation of ventilation with constant quantity EA, SA FAN– operation of the constant regular Air flow intensity
Operation of air conditioning and heating (Peltier module applied) Modifiable operation between cooling and heating according to user situation

Exposure installation (ceiling/wall mounted)total heat exchanger device features

  • · Dedicated product for ventilation
  • · Air flow intensity control by 5 stages: economy, light, medium, strong, very strong(negative and positive pressure system operation)
  • · Function of inside device cleaning operation for preventing the re-influx of adhesive pollutant(odor/dust) in the device
  • · Specification of Filter application: PRE Filter– carbon coated nonwoven Filter / Medium Filter 10~20T- grade of H12 Hepa Filter
  • · Application of PCT heater: temperature modification for winter OA influx(10~15 ℃ UP)