Product Introduction

Application Type for Specialized Building

Special purpose building heat recovery ventilation system(school/classroom) structure map for floor/stand type total heat exchanger

Standard equipment of floor/stand type heat recovery ventilation device for special purpose building

img

I.C.W Indoor Cleaning Work (operation system for inside cleaning)

img

Standard specification/data for K-Air specialized heat recovery ventilation device

Model CMH
(economy, light, medium, strong, very strong)
Product standard
(L*W*T)
Connector standard
(Flange)Φ
Consumption of power
(W)
Power
KAV-45PST 450 1200*640*360 200*2/250(½)
under 320 200V
60Hz
KAV-50PST 500 1200*640*360 125/100 under 350
KAV-80SST 800 1800*550*360 200*2/250(½) under 450
KAV-100SST 1000 850*500*650 250 under 500

Operation Function of K-AIR specialized heat recovery ventilation device(school/classroom)

Operation mode Running mode
Turned on
ICW/PDT mode ON
Exhaust fan operation - in very strong operation mode for 20seconds
3seconds off for preventing the re-influx of exhaust particle
Normal operation Air flow intensity control adjustable
Air flow intensity control by 5 stages economy, light, medium, strong, very strong
Negative pressure system operation Operation with exhaust priority EA – strong, medium SA – light, economy
Operation of positive pressure Operation with Supply priority: SA – strong, medium EA – light, economy

Features of Floor/stand heat recovery ventilation device for special purpose building

  • · Standard customized heat exchanger(cooling not less than 45%, heating not less than 75%)
  • · Air flow intensity control by 5 stages: economy, light, medium, strong, very strong(negative and positive pressure system operation)
  • · Inside device cleaning to prevent for the re-influx of internal adhesive pollutant(odor,dust) into inside
  • · Specification of operation function Filter application: PRE Filter- carbon coated nonwoven Filter/Medium Filter -Hepa Filter of H12 grade
  • · Integrated type of Supply and exhaust with Optional choice structure within 1 hole1/2 devided duct/ separated 2 hole type
  • · Low-noise design available at school class
  • · Application of separated front 2 doors for Filter managing convenience