Product Introduction

Vehicle-Mounted Heat Recovery Ventilation device

Structure map and Standard specification·feature of with DC12V for high-occupancy/caravan with sensible heat ventilation system and installation of sub-cooling function

Vehicle DC12V multi-seater/caravan sensible heat ventilation system

  • · Caravan exclusive(Rooftop installed, operation with engine off)
  • · Truck exclusive(Rooftop installed, operation with engine off)
img
img

Specification of K-Air DC12V for high-occupancy/caravan vehicle purpose model

Model Air flow intensity MAX
(CMH)
Product standard
(L*H*W)
Modification of operation
Consumption of power
(W)
Power
KAV-8PA(caravan, Truck) Peltier type 80 700*500*250 Air flow intensity control by 5 stages
(economy, light, medium, strong, very strong)

operation with engine off
300 DC12V,
battery exclusive
KAV-8AA(caravan) Air conditioner type 80 500
KAV-10PA(caravan, Truck) Peltier type 100 350
KAV-10PA(caravan, Truck) Peltier type 100 550

Standard operation function for K-Air DC12V for high-occupancy/caravan vehicle purpose model

Operation mode Running mode
At the Initial operation of device(turned on)
I.C.W / P.D.T(Indoor Cleaning Work / Particle Down Time)
I.C.W operation /EA FAN in very strong operation mode for 20seconds
SA FAN – Off / ICW MD : Open /outside air MD: Off
For prevention of re-influx of P.D.T exhaust dust, entire device is turned off for 10 seconds
Negative pressure system operation(operation with exhaust priority)- operation for removing droplet EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Function of enforcing air conditioning Peltier module applied: constant indoor temperature even at ventilation
hybrid Air conditioner: ventilation / air conditioner operation cooling Kcal/h: not less than 2,000
Positive pressure operation(operation with supply priority) – operation for reducing CO2 EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Operation with engine off available Operation with DC12V is available with engine off through supplementary battery

Features of vehicle purpose DC12V for high-occupancy vehicle/caravan

  • · Dedicated product for ventilation
  • · Air flow intensity control by 5 stages: economy, light, medium, strong, very strong(negative and positive pressure system operation)
  • · function of inside device cleaning operation for preventing the re-influx of adhesive pollutant(odor/dust) in the device
  • · Specification of Filter applied: carbon coated nonwoven Filter/Medium Filter -Hepa Filter of H12 grade
  • · Peltier module applied: temperature compensating function cooling and heating applied(compensating temperature loss even at ventilation)
Sensible heat ventilation system for DC24V Bus Rooftop Type
  • Rooftop installation type

    • · Supply and exhaust integrated AIR VEN type
    • · Duct composition type
  • Hybrid air conditioner (in process destined to be launched in the year 2025)

    • · 28kw level
    • · Application to large-sized bus
img

Interoperation of air conditioner and heater at installation on Bus Roof Top

  • · Cooling & Heating effect of A/L heat exchanger can be expected through indoor temperature heat storage at air conditioning and heating
  • · Function of maintaining optimal indoor temperature of reduced temperature gap between indoor and outdoor by preventing up and down of indoor temperature and the unpleasant feeling of passenger directly exposed to hot or cold air of outside 60℃(temperature of bus looftop as standard)

Specification of K-Air DC24V Bus Roof Top for vehicle purpose

Model Air flow intensity MAX
(CMH)
Product standard
(L*H*W)
Modification of operation
Consumption of power
(W)
Power
KAV-100B(large-sized type) 1000 900*500*200 Air flow intensity control by 5 stages
(economy, light, medium, strong, very strong)
240 DC24V
KAV-80B(medium-sized type) 800 500*300*150 90
KAV-50B(small-sized type) 500 300*200*100 60

Standard operational function of K-Air DC24V Bus Roof Top for vehicle purpose

Operation mode Running mode
At the Initial operation of device(turned on)
I.C.W / P.D.T(Indoor Cleaning Work / Particle Down Time)
I.C.W operation /EA FAN in very strong operation mode for 20seconds
SA FAN - OFF
Outside air MD: OFF/P.D.T preventing the re-influx of exhaust dust
10 seconds of being turned off for the entire device
Negative pressure system operation(operation with exhaust priority)- operation for removing droplet EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Interoperation(operation of heat storage) of air conditioner and heater for cooling and heating
System operation at running
EA FAN– OFF / outside air MD: OFF
SA FAN–economy(ON) / heat storage MD: Open
Operation of positive pressure(operation with supply priority) operation for reducing CO2 EA FAN –operation in medium, strong / SA FAN – operation in economy, light, medium
Operation of ventilation with constant quantity EA, SA FAN– operation of the constant regular Air flow intensity

img